! This version of Internet Explorer is not supported anymore !

We recommend to visit our website with another browser (Microsoft Edge, Chrome, Firefox, ...)

Presence detector, 230 V, master, 2 channels, 24 m, IP54, for flush mounting, white

Reference code
350-20072
Technical datasheets
Technical manuals
Certificaten CE-Marking

Description

This presence or absence detector with two channels (360°, 10 A) is suitable for flush mounting on ceilings and is used to switch indoor lighting or ventilation on and off. The detector has a circular detection area with a diameter of up to 24 m that can be adjusted using the cover mask. The device with integrated light sensor allows to set up each channel separately as a presence or as an absence detector. When used as a presence detector, the lighting automatically switches on and off (as soon as the switch-off delay has elapsed). When used as an absence detector, the lighting must always be manually switched on first using an N.O. push button, after which it will be automatically switched off (as soon as the switch-off delay has elapsed). The device is also equipped with the ‘eco off’ function, which allows the user to switch the lighting off using a connected N.O. push button without having to wait for the switch-off delay. If the lighting is not switched off manually, it will be switched off automatically once the switch-off delay has elapsed. The device has an IP54 protection degree and two potential-free contacts. The set-up can be performed manually on the device itself or via a remote control. The product can be used as a stand-alone unit or in combination with a maximum of ten secondary detectors.

Finishing colour: white

Compatible secondary detectors: 350-20071, 350-20079, 350-20081

Specification description

Presence detector, 230 V, master, 2 channels, 24 m, IP54, for flush mounting, white.

  • Factory setting
    • sensitivity of the motion sensor: high
    • application: presence detector, daylight-dependent, automatic on/off via PIR
    • push-button application: in the mode: 'eco off', the lighting can be switched off manually with a short push on a NO push button without having to wait for the switch-off delay. The lighting can also be switched on manually with a short push on the push button. The lighting is only switched on. The lighting is only switched on if the amount of daylight available in the room is insufficient. Pressing and holding the push button switches the lighting on or off for two hours irrespective of the detected movement and the registered light level.

- switch-off delay both channels: 10 min

- light sensitivity both channels: 200 lux

The detector has four potentiometers and six DIP switches for manually adjusting the settings:

– potentiometer 1: setting the light sensitivity for channel 1 (20 lux up to light-independent)

– potentiometer 2: setting the switch-off delay for channel 1 (2 up to 60 minutes)

– potentiometer 3: setting the light sensitivity for channel 2 (20 lux to light-independent)

– potentiometer 4: setting the light sensitivity for channel 2 (2 to 60 minutes) For correct setting, the detector must have an LED indicator for setting of time and lux level The four DIP switches enable the selection of various functionalities: presence or absence detection, ‘eco off’ function, daylight-dependent or daylight-independent push button. Using the two DIP switches the sensitivity of the sensor can be increased or decreased (four levels of sensitivity). Setting via the remote control: the user can use the remote control to set up the detector entirely according to his requirements (absence, presence, lux levels, push button possibilities, switch-off delay, four levels of sensitivity ..)

  • Detector technology: PIR
  • Input voltage: 230 Vac ± 10 %, 50 Hz
  • Detector output: 230 V (ON/OFF)
  • Maximum MCB rating: 10 A (limited by national installation rules)
  • Number of channels: 2 channels
  • Light intensity range: 20 lux – 1000 lux, ∞
  • Switch-off delay: pulse, 2 min – 1 h
  • Detection angle: 360°
  • Detection range (PIR): ø 24 m from a height of 3 m
  • Ambient temperature: -5 – +50 °C
  • Mounting method: flush-mounting
  • Mounting height: 2 – 3.4 m
  • Usage: for indoor use only
  • Relay contact: 2 x N.O. (max. 10 A), potential-free
  • Potential-free contact: NO, 230 V, µ10 A
  • Maximum load incandescent and halogen lamps (cosφ = 1): 2300 W
  • Maximum load low voltage halogen lamps: 500 W
  • Maximum load economy lamps (CFLi): 350 W
  • Maximum load LED lamps 230 V: 350 W
  • Maximum capacitive load: 140 µF
  • Maximum switching current: 165 A/20 ms – 800 A/200 µs
  • Dimensions (HxWxD): 100 x 100 x 136.4 mm
  • Dimensions visible (HxWxD): 100 x 100 x 46.4 mm
  • Protection degree: IP54
  • Protection class: Class I device
  • Marking: CE
  • Certification marks: SundaHus, Byggvarubedömningen

Select a product below to view related articles, variants or accessories:

Favorites ( 0 )