Presence or absence detector, 360°, 230V, 24 m, master, two channels, for surface mounting

The presence or absence detector with two channels and daylight control for surface mounting in ceilings is suitable for switching indoor lighting or ventilation on and off. The detector is equipped with an integrated light sensor. Automatic on/off (presence detector) or manual on/automatic off (absence detector). The detection area can be divided by means of an adjustable cover mask. In conformity with the European directive for EMC and safety EN60669-2-1.

Product details

This product consists of several components. Below you will find an overview of all the component parts.

Presence or absence detector PIR 360°, 230 V, 2 channels, 24 m, master, for surface-mounting. (white)

Reference code
350-20082

This presence or absence detector with two channels (360°, 10 A) is suitable for surface-mounting on ceilings and is used to switch indoor lighting or ventilation on and off. The detector has a circular detection area with a diameter of up to 24 m that can be adjusted using the cover mask. The device with integrated light sensor allows to set up each channel separately as a presence or as an absence detector. When used as a presence detector, the lighting automatically switches on and off (as soon as the switch-off delay has elapsed). When used as an absence detector, the lighting must always be manually switched on first using an NO push button, after which it will be automatically switched off (as soon as the switch-off delay has elapsed). The device is also equipped with the ‘eco off’ function, which allows the user to switch the lighting off using a connected NO push button without having to wait for the switch-off delay. If the lighting is not switched off manually, it will be switched off automatically once the switch-off delay has elapsed. The device has an IP54 protection degree, two potential-free contacts and conforms to the European EN 60669-2-1 standard for EMC and safety. The set-up can be performed manually on the device itself or via a remote control. The product can be used as a stand-alone unit or in combination with a maximum of ten slaves.

Finishing colour: white.

Specification description

Presence or absence detector PIR 360°, 230 V, 2 channels, 24 m, master, for surface-mounting. (white). The detection area can be divided by means of an adjustable cover mask. Factory settings:

  • sensitivity of the motion sensor: high
  • application: presence detector, daylight-dependent, automatic on/off via PIR
  • push-button application: the lighting can be switched off manually with a short push on a NO push button without having to wait for the switch-off delay (mode: 'eco off'). The lighting can also be switched on manually with a short push on the push button. The lighting is only switched on. The lighting is only switched on if the amount of daylight available in the room is insufficient. Pressing and holding the push button switches the lighting on or off for two hours irrespective of the detected movement and the registered light level.
  • switch-off delay both channels: 10 min
  • light sensitivity both channels: 200 lux

The detector has four potentiometers and six DIP switches for manually adjusting the settings:

  • potentiometer 1: setting the light sensitivity for channel 1 (20 lux up to light-independent)
  • potentiometer 2: setting the switch-off delay for channel 1 (2 up to 60 minutes)
  • potentiometer 3: setting the light sensitivity for channel 2 (20 lux to light-independent)
  • Potentiometer 4: setting the switch-off delay for channel 2 (2 to 60 minutes)

For correct setting, the detector must have an LED indicator for setting of time and lux level The four DIP switches enable the selection of various functionalities: presence or absence detection, ‘eco off’ function, daylight-dependent or daylight-independent push button. Using the two DIP switches the sensitivity of the sensor can be increased or decreased (four levels of sensitivity). Setting via the remote control: the user can use the remote control to set up the detector entirely according to his requirements (absence, presence, lux levels, push button possibilities, switch-off delay, four levels of sensitivity ..)

Technical data

  • Input voltage: 230 Vac ± 10 %, 50 Hz
  • Number of channels: 2 channels
  • Light intensity range: 20 lux – 1000 lux
  • Switch-off delay: 2 min – 1 h, ∞
  • Detection angle: 360 °
  • Detection range (PIR): up to 24 m in diameter from a height of 3 m
  • Ambient temperature: -5 – 50 °C
  • Mounting method: surface mounting
  • Mounting height: 2 – 3,5 m
  • Relay contact 1: NO (max. 10 A), potential-free, light- and motion-sensitive
  • Wire capacity: 3 x 2.5 mm² per connection terminal
  • Maximum load incandescent and halogen lamps (cosφ=1): 2300 W
  • Maximum load low voltage halogen lamps: 1200 W
  • Maximum load economy lamps (CFLi): 350 W
  • Maximum load LED lamps 230 V: 350 W
  • Maximum capacitive load: 140 µF
  • Maximum switching current: 165 A/20 ms – 800 A/200 µs
  • Dimensions (HxWxD): 117.3 x 117.3 x 64.1 mm
  • Protection degree: IP54
  • Protection class: Class I device
  • Marking: CE

Accessories

Technical datasheets
Technical manuals

IR remote control for presence or absence detectors (360°, 230 V, master) with one channel for flush mounting (350-20070) and for surface mounting (350-20078)

Reference code
350-20089

This remote control is used for setting the presence or absence detectors (360°, 230 V, master) with one channel for flush mounting (350-20070) and for surface mounting (350-20078) via infrared transmission. The remote control allows the factory settings to be changed, including the daylight factor (lux value) and the time period during which the lighting remains on.

Specification description

This Niko remote control is used for setting the presence or absence detectors (360°, 230 V, master) with one channel for flush mounting (350-20070) and for surface mounting (350-20078) via infrared transmission. The factory settings can be changed with the remote control. The settings that can be changed include the daylight factor (lux value) and the time period during which the lighting remains on.

Universal remote control for smartphone

Reference code
350-41936

The universal remote control is used for the configuration of detectors via a smartphone app. The Niko Sensor Tool app is used to define settings and configuration and the universal remote control transmits the settings and configuration from the smartphone to the detector wirelessly.

Related products

Outdoor motion detector, 180°, 230 V, 16 m

The outdoor motion detector with one channel to be surface mounted on a wall or partition is suitable for use on driveways and in gardens. Equipped with an integrated light sensor. Automatic on/off (after switch-off delay) or manual on/off via an NC push button (to be ordered separately). The detection area can be divided by means of an adjustable cover mask. In conformity with the European directive for EMC and safety EN60669-2-1.

Outdoor motion detector, 180°, 230 V, 13 m, black

The outdoor motion detector with one channel to be surface mounted on a wall or partition is suitable for use on driveways and in gardens. Equipped with an integrated light sensor. Automatic on/off (after switch-off delay) or manual on/off via an NC push button (to be ordered separately). The detection area can be divided by means of an adjustable cover mask. In conformity with the European directive for EMC and safety EN60669-2-1.

Outdoor motion detector, 180°, 230 V, 16 m, with orientable lens

One-channel outdoor motion detector for use along driveways, in gardens, ... Provided with an integrated light sensor. Automatically on or manually on via a NC push button (230 V) (to be ordered separately). Automatically off after switch-off delay. Provided with a rotatable motion sensor. The detection area can be subdivided by means of an adjustable cover mask. In conformity with the European directive for EMC and safety EN60669-2-1.

Favorites ( 0 )