Product details

This product consists of several components. Below you will find an overview of all the component parts.
  • Presence or absence detector, 10 A, PIR 360°, 230V, 24 m, master, two channels, for flush-mounting (white)

    Add to 'My favorites' Remove from 'My favorites'
    350-20072

    Description

    This presence or absence detector with two channels (360°, 10 A) is suitable for flush mounting on ceilings and is used to switch indoor lighting or ventilation on and off. The detector has a circular detection area with a diameter of up to 24 m that can be adjusted using the cover mask. The device with integrated light sensor allows to set up each channel separately as a presence or as an absence detector. When used as a presence detector, the lighting automatically switches on and off (as soon as the switch-off delay has elapsed). When used as an absence detector, the lighting must always be manually switched on first using an N.O. push button, after which it will be automatically switched off (as soon as the switch-off delay has elapsed). The device is also equipped with the ‘eco off’ function, which allows the user to switch the lighting off using a connected N.O. push button without having to wait for the switch-off delay. If the lighting is not switched off manually, it will be switched off automatically once the switch-off delay has elapsed. The device has an IP54 protection degree, two potential-free contacts and conforms to the European EN 60669-2-1 standard for EMC and safety. The set-up can be performed manually on the device itself or via a remote control. The product can be used as a stand-alone unit or in combination with a maximum of ten slaves.

    Finishing colour: white.

    Specification description

    Presence or absence detector, 10 A, PIR 360°, 230V, 24 m, master, two channels, for flush-mounting (white). The detector is suitable for the operation of indoor lighting or ventilation or … in small or large offices, warehouses .. The two channels can be set separately. The detector must have an on/off control with two channels (potential-free relay output), and inputs which can be overridden from a 230 V switch. It must be possible to override each relay output via a separate switch. The detection area can be divided by means of an adjustable cover mask. The detector is equipped with an integrated light sensor which switches off as soon as sufficient daylight is measured in the room. The detection area of the detector can be increased by connecting a maximum of 10 slaves to the master. The detector can be used with factory settings, the settings can be manually adjusted on the device or with a remote control. The lighting can be controlled in the following ways:

    • presence or absence detector for channel 1
    • presence or absence detector for channel 2
    • short press of the push button to turn on or (Eco) off. This allows you to decide whether or not to wait for the switch-off delay. Long press to turn on/off during disconnection time + two hours
    • pressing the push button briefly to switch on the lighting can be made both daylight-dependent and daylight-independent
    • briefly pressing or holding down the push button to turn off the light can be blocked, so that no-one can turn off the light The detection area can be divided by means of an adjustable cover mask. Factory settings:
    • sensitivity of the motion sensor: high
    • application: presence detector, daylight-dependent, automatic on/off via PIR
    • push-button application: in the mode: 'eco off', the lighting can be switched off manually with a short push on a NO push button without having to wait for the switch-off delay. The lighting can also be switched on manually with a short push on the push button. The lighting is only switched on. The lighting is only switched on if the amount of daylight available in the room is insufficient. Pressing and holding the push button switches the lighting on or off for two hours irrespective of the detected movement and the registered light level.

    - switch-off delay both channels: 10 min

    - light sensitivity both channels: 200 lux

    The detector has four potentiometers and six DIP switches for manually adjusting the settings:

    • potentiometer 1: setting the light sensitivity for channel 1 (20 lux up to light-independent)
    • potentiometer 2: setting the switch-off delay for channel 1 (2 up to 60 minutes)
    • potentiometer 3: setting the light sensitivity for channel 2 (20 lux to light-independent)
    • potentiometer 4: setting the light sensitivity for channel 2 (2 to 60 minutes) For correct setting, the detector must have an LED indicator for setting of time and lux level The four DIP switches enable the selection of various functionalities: presence or absence detection, ‘eco off’ function, daylight-dependent or daylight-independent push button. Using the two DIP switches the sensitivity of the sensor can be increased or decreased (four levels of sensitivity). Setting via the remote control: the user can use the remote control to set up the detector entirely according to his requirements (absence, presence, lux levels, push button possibilities, switch-off delay, four levels of sensitivity ..)
    • Input voltage: 230 Vac ± 10 %, 50 Hz
    • Number of channels: 2 channels
    • Light intensity range: 20 lux – 1000 lux, ∞
    • Switch-off delay: pulse, 2 min – 1 h
    • Detection angle: 360 °
    • Detection range (PIR): up to 28 m in diameter from a height of 3 m
    • Ambient temperature: -5 – 50 °C
    • Mounting method: flush-mounting
    • Mounting height: 2 – 3,4 m
    • Relay contact 1: NO (max. 10 A), potential-free, light- and motion-sensitive
    • Relay contact 2: NO (max. 10 A), potential-free, light- and motion-sensitive
    • Potential-free contact: NO, 230 V, µ10 A
    • Maximum load incandescent and halogen lamps (cosφ=1): 2300 W
    • Maximum load low voltage halogen lamps: 500 W
    • Maximum load economy lamps (CFLi): 350 W
    • Maximum load LED lamps 230 V: 350 W
    • Maximum capacitive load: 140 µF
    • Maximum switching current: 165 A/20 ms – 800 A/200 µs
    • Dimensions (HxWxD): 100 x 100 x 136.4 mm
    • Protection degree: IP54
    • Protection class: Class I device
    • Marking: CE